Description
The UT202BT is an easy-to-use smart clamp multimeter with Bluetooth that can automatically detect most common parameters - AC/DC voltage, AC current, resistance and line continuity. Displays true rms values.
Capacitance measurement and non-contact voltage measurement (NCV) are selected by pressing buttons. The UT202BT has a novel design, high reliability and safety, as well as automatic range change available for all functions. Backlit dual LCD display with a maximum display value of ±9999 can simultaneously display voltage/current, voltage/frequency, current/frequency.
There is an LED lamp on the underside of the clamping jaws. It is powered by two AAA 1.5V R03 batteries.
The multimeter is designed according to safety standards EN61010-1/ 61010-2-032 and electromagnetic compatibility EN61326-1/EN61326-2-2 and complies with CAT III 600V, double insulation and pollution level II.
Product parameters:
- measurement of AC/DC voltage, AC current, resistance, capacity, temperature and circuit continuity
- voltage and current frequency measurement on the auxiliary display
- non-contact electric field sensing (NCV)
- multi-segment backlit dual LCD display
- sound and optical alarm
- protection against voltage greater than 600V on all ranges
- automatic range switching
- accuracy is guaranteed within 5% to 100% of ranges
- built-in LED flashlight
- powered by two AAA 1.5V R03 batteries
Technical parameters :
To ensure measurement accuracy, the operating temperature should be in the range of 18°C - 28°C
1a. AC current measurement (ranges/resolution/accuracy):
9.999A / 0.001A / 50Hz to 60Hz ±(2.5%+30)
99.99A / 0.01A / 50Hz to 60Hz ±(2.5%+5)
600.0A / 0.1A / 50Hz to 60Hz ±(2.5%+5)
- minimum identifiable current: 0.01A
- the frequency display when measuring AC current is normative if the current amplitude is ≥1Arms at a frequency of 40Hz to 100Hz
- overload protection at 600 Arms
1b. AC-LPF current measurement ( ranges / resolution / accuracy ):
6000A / 0.1A / 50Hz to 60Hz ±(4.0%+5) / 600A rms
1c. Measurement of AC-trigger current ( ranges / resolution / accuracy ):
99.99A / 0.01A / 50Hz to 60Hz ±(10%+10) / 600A rms
6000A / 0.1A / 50Hz to 60Hz ±(10%+10) / 600A rms
2a. AC voltage measurement ( range / resolution / accuracy ):
9.999V / 0.001V / 40Hz to 400Hz ±(0.8%+3)
99.99V / 0.010V / 40Hz to 400Hz ±(0.8%+3)
600.0V / 0.1V / 40Hz to 400Hz ±(0.8%+3)
- the frequency display on the auxiliary display when measuring AC voltage is normative if the input voltage has an amplitude of ≥5Vrms at a frequency of 40Hz to 1000Hz. At frequency above 400Hz accuracy is not specified.
- input impedance approx. 10MGΩ
- overload protection at 600Vrms
- minimum identifiable voltage 0.6V
2b. AC-LPF voltage measurement ( range / resolution / accuracy ):
600V / 0.1V / 40Hz to 400Hz ±(2.0%+5) / 600V rms
3. DC voltage measurement ( range / resolution / accuracy ):
9.999V / 0.001V / ±(0.5%+3)
99.99V / 0.01V / ±(0.5%+3)
600V / 0.1V / ±(0.5%+3)
- input impedance approx. 10MΩ
- overload protection at 600Vrms
- minimum identifiable voltage 0.6V
4. Resistance measurement (ranges/resolution/accuracy):
999.9Ω / 0.1Ω / ±(0.8%+3)
9.999kΩ / 0.001kΩ / ±(0.8%+3)
99.99kΩ / 0.01kΩ / ±(0.8%+3)
999.9kΩ / 0.1kΩ / ±(0.8%+3)
9.999MΩ / 0.001MΩ / ±(1.5%+3)
99.99MΩ / 0.01MΩ / ±(2.0%+5)
- overload protection at 600 Vrms
- open circuit voltage approx. 1V
5. Capacity measurement (ranges/resolution/accuracy):
99.99nF / 0.01nF / ±(4.0%+10)
999.9nF / 0.1nF / ±(4.0%+10)
9.999nF / 0.001μF / ±(4.0%+5)
99.99μF / 0.01μF / ±(4.0%+5)
999.9μF / 0.1μF / ±(4.0%+5)
9.999mF / 0.001mF / ±(10.0%+10)
99.99mF / 0.1mF / ±(10.0%+10)
- overload protection at 600 Vrms
6. Checking the continuity of circuits:
- If the measured resistance is ≤30Ω, the circuit is in good conduction condition, the buzzer will beep and the LED will turn green. If the measured resistance is ≥70Ω (open circuit), the buzzer will not make any sound and the LED will turn red. If the circuit resistance is between 30Ω and 70Ω, the condition is undefined.
- open circuit voltage about 3.0V
- overload protection at 600 Vrms
7. Temperature measurement:
-40°C~1000°C / ±(2.0%+5)
8. Non-contact electric field sensing (NCV):
- allows detecting live conductors acoustically using a buzzer and optically using an LED
Other parameters:
- pliers opening: 28mm
- measurement of maximum and minimum values: yes
- data retention (HOLD): yes
- low battery indication: yes, if the battery voltage is less than 2.4V, if the battery voltage is less than approx. 2.2V, the device cannot be turned on
- auto power off: yes, the multimeter will automatically power off if no button is pressed within 15 minutes. This feature can be disabled as needed.
- resistance to falling: yes, 1m
- electromagnetic compatibility: RF≤1V/m overall accuracy = stated accuracy +5% of range, if RF>1V/m then accuracy not specified
- operating altitude: ≤ 2000m
- operating temperature and humidity: 0 to +30°C (≤ 80%RH), 30 to 40°C (≤ 75%RH), 40 to 50°C (≤ 45%RH)
- storage temperature and humidity: -20 to +60°C (≤ 80%RH)
- recommended calibration interval: 1 year
- power supply: 2 batteries 1.5 V (R03)
- product dimensions: 201.5 × 47 × 28.5 mm
- weight: approx. 241g (including batteries);
- product color: red and gray
Package contents :
- clamp multimeter UT202BT: 1pc
- test cables: 1 pair
- temperature probe (K): 1pc
- battery 1.5 V (R03): 2 pcs
- instructions for use: 1 pc
Manufacturer: UNI-TREND
Documents available for download
Nobody has entered comment on this product yet. Be first!