Description
Immax NEO Smart three-phase circuit breaker 10-63A with residual current device, consumption measurement, 3P+N, Zigbee 3.0 is designed for alternating current circuits 50/60 Hz with a nominal voltage of 230 /400 V and a switching current of 10A, 32A, 40A, 50A, 63A (adjustable in the Immax NEO PRO application). Complies with the standards ČNS EN 61009–1. Tripping characteristics B, C, D, depending on the settings in the Immax NEO PRO application.
It ensures disconnection, switching and protection of electrical circuits against ground fault currents, thus ensuring fire protection and at the same time the function of a circuit breaker - i.e. protection against short circuit and thermal overload. This type of RCBO also disconnects the working conductor. The control of the middle (working) conductor of the "neutral" is carried out in such a way that when switching on, "N" is first connected and then only the phase, and when switching off, the phase is first disconnected and then only "N". This is for reasons of higher safety. The "N" circuit thus protects from the first phase of switching on until the end of switching off. Immax NEO PRO application in Czech and 60 other languages compatible with iOS, Android and also with TUYA systems.
Technical parameters:
Protocol: Protocol: ZigBee 3.0
Zigbee frequency: 2.405~2.480GHz
Maximum output power: +10dBm, output power dynamics >35dB
Communication protocol: Support Zigbee, Tuya.
Wireless range: direct visibility 30m, in built-up areas 10m.
Zigbee repeater: yes
Mains standby power (Pnet): 0.4W
Rated operating voltage: AC 230V/400V
Current frequency: 50/60 Hz
Maximum rated current: 63 A
Short-circuit breaking capacity (Ics): 6000 A
Current fuse: 10A, 32A, 40A, 50A, 63A (adjustable in the application)
Load characteristics: B, C, D (according to the settings in the application)
Operating position indicator: yes
Overvoltage protection: 220-265 V (adjustable in the application)
Undervoltage protection: 150-250V (adjustable in the application)
Thermal fuse, overheating protection: yes
Current fuse, overvoltage and overload protection: yes
Mechanical life: 10,000 switching
Electrical life: 3,000 switching
Automatic restart after power failure:
In automatic mode: If no fault is detected, the device will automatically restart within 3 seconds.
In manual mode: The device cannot be automatically restarted
Operating temperature: -25 °C to 70 °C
Material: PC V0 flame retardant
Mounting: On a standard DIN rail 35.5 × 7.5 mm.
Wire connection terminals
Maximum wire cross-section: 35 mm2
Pollution degree: 2
Dimensions: 135 x 90 x 74 mm
Weight: 504 g
Protection degree: IP20
Package contents: circuit breaker, antenna, user manual