Description
The UT622C LRC device is a hand-held meter of components - coils (inductance), resistors (resistance) and capacitors (capacitance) and their secondary properties: D (loss factor), Q (quality factor), Θ (phase angle in degrees), Θ (phase angle in radians) and ESR (equivalent series or parallel resistance). The parameters of the components are measured by alternating voltage with a selectable frequency of 100, 120, 1000, 10000 Hz, 100kHz and a selectable amplitude of 0.1Vrms, 0.3Vrms, 1.0Vrms at the output impedance of the signal source 100Ω. The highest measurement accuracy is 0.1%.
The device has an intuitive TFT LCD display with a diagonal of 2.8 inches and adjustable backlight brightness in ten levels, a built-in large-capacity Li-Pol battery 1800mAh and a miniUSB connector for charging and data transfer to a PC. The maximum display value when measuring primary parameters is 99999 and the minimum value when measuring secondary parameters is 0.0001. Measurement mode - one measurement triggered by the TRI button or a command from the PC; or continuous measurement with adjustable test trigger speed 20x/sec, 5x/sec, 2x/sec. Configuration of 2+1 or 4+1 terminals (with the UTR-L100k-H test cables included in the delivery of this device).
Due to its technological sophistication, the device is also suitable for professional purposes - in connection with a computer (PC), it creates a station for sorting components according to the specified tolerance parameters and can be used in production lines, laboratories, etc.
Product parameters :
- manual RLC meter of primary and secondary parameters of components
- large backlit, intuitive TFT LCD display, 10 levels of brightness
- the diple range is a maximum of 99999
- highest accuracy 0.1%
- the possibility of selecting components according to the specified tolerance
- measurement with alternating voltage 100, 120, 1000, 10000 Hz or 100kHz
- selectable amplitude meas. voltage 0.1Vrms, 0.3Vrms, 1.0Vrms
- selection of equivalent mode (for Z <100Ω serial, for Z >10kΩ parallel)
- automatic component identification
- built-in large-capacity Li-Pol battery: 3.7V/1800 mAh
- power supply + charging: adapter DC 5V ±0.25V, >1A
- operation on one battery charge: typically 8 hours
- functions in data recording and statistics mode: AVG, MAX, MIN
- sound tone when pressing buttons: yes, can be turned off / on
- option to lock buttons: yes
- automatic shutdown: yes, after 5, 15, 30, 60 minutes, or off
- data interface: mini USB
- data transfer rate to PC: 9600/19200/38400 Baud
- acoustic and optical alarm comparing tolerance results: off, passes, does not pass
- sound alarm selection: short beep, long beep, two short beeps
- resetting the tester in the event of an open or shorted circuit: yes
- tolerance value setting from nominal: 1% to 20%, default 5%
- counting of components: all, compliant, non-compliant
Technical parameters :
- Measurement range of primary impedance parameters:
type // display range // minimum resolution on the range
inductance L // 0.001 μH to 9999.9 H // 1 / 0.1 / 0.01 / 0.001 μH
capacitance C // 0.001 pF to 99.999 mF // 1 / 0.1 / 0.01 / 0.001 pF
resistance R // 0.0001 Ω to 99.999 MΩ // 0.0001 Ω
general impedance Z // 0.0001 Ω to 99.999 MΩ // 0.0001 Ω
- Measurement range of secondary impedance parameters:
type // display range // minimum resolution on the range
loss factor D // 0.0001 to 9.9999 // 0.0001
quality factor Q // 0.0001 to 99999 // 0.0001
phase angle in degrees Θ deg // -179.9° to 179.99° // 0.01°
phase angle in radians Θ rad // -3.142 rad to 3.1416 rad // 0.001 rad
equivalent resistance ESR // 0.01 mΩ to 999.99 Ω // 0.01 mΩ
- display: backlit TFT LCD display with a diagonal of 2.8" with a resolution of 320 x 240 pixels
- display range: maximum 99999
- accuracy: best 0.1%
- selection of components according to the set tolerance: yes
- voltage measurement: AC 100, 120, 1000, 10000 Hz or 100kHz
- amplitude meas. voltage: 0.1 Vrms, 0.3 Vrms, 1.0 Vrms
- data transfer to PC: yes, after installing the software on the PC
- power supply: Li-Pol battery 1800mAh and/or adapter DC 5V ±0.25V, >1A
- automatic charging management: even when the device is switched off
- charging and data interface: mini USB
- working environment: temperature 5 to 35°C, humidity ≤80%°C
- weight without batteries / with accumulator: 305g / 420g
- product dimensions (H x W x D): 192 x 93 x 44 mm
- package dimensions: 225 x 220 x 63 mm
- safety and EMC certification: IEC/EN61010-1: 2010, EN61326-2: 2013, EN61326-2-2: 2013
Contents of individual packaging :
- device UT622C: 1 pc
- USB interface cable: 1 pc
- power adapter 5V/1A: 1 pc
- four-pole test cables UTR-L100k-H: 1 pc
- gold-plated short circuit board UTR-001: 1pc
- instructions for use: 1 pc
Packaging for bulk customers :
- standard quantity per carton: 10 pcs
- standard carton dimensions: 370 x 305 x 475 mm
- gross weight of the carton: approx. 13.2 kg
MANUFACTURER: UNI-TREND
www.uni-t.cz
Documents available for download